Update: I ordered and received the Johnson Temp control. Since I already had the wire for the three fans running up through the drain hole, I figured I would run the temp probe the same way. When I pulled all the drawers out and looked at the back where the drain comes out, the drip pan (sits on top of the compressor) was kinda in the way. It pops off, so I removed it. The temp probe still wouldn't go up in the drain tube. I could tell by looking at the drain from the inside that it has an insert that makes the drain smaller. I took a pair of pliers with a screw driver handle and gently tapped the drain from the bottom and it came loose on the inside and I removed it. That made the drain hole just big enough that I could run the temp probe up through it. I'm going the seal it up with the electricians putty that Shilala recommended. It is scheduled to be delivered today. I set the temp at 65. I have never used a temp controller before so I asked a couple more questions of TG and he has answered them and I thank him for his recommendations and help choosing the temp controller and his help in the settings.

I have the setting for the setpoint at 65 F. There is also a setting for differential and as TG explained it that is the temp that it will go to below the setpoint before it cuts the fridge off. The differential comes defaulted at 5 degrees. So with the setpoint at 65 with a differential of 5 it will go down to 60 degrees before it cuts off. TG explained that if you have the differential too close to the set point it will cycle the compressor too often and for very short periods leading to premature failure of the comoressor, so he said 5 is good. I am waiting for the thing to stabilize since it was empty for an hour or two while i was working on it and will update soon.
G G is offline   Reply With Quote
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT -6. The time now is 01:03 PM.


Powered by vBulletin® Version 3.7.4
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
All content is copyrighted jointly by Cigar Asylum and the content provider.