OK here is the situation:

I have 3 hygrometers:

#1 is a digital that I have checked with the salt test and it came out at 75% dead nuts. When I put this hygrometer in my humidor with 65% HF beads it reads right on at 65%.

#'s 2 and 3 are HydroSet II digital hygrometers which I recently bought. I salt tested both of them over the course of the past few days and have gotten them dialed in to 75% using the same salt test as I did #1. I am using this setup to do the test, a small glass dish with a clip-on lid that is airtight:


However, after calibrating them to 75% with the salt test, when I put either or both of the two new HydroSet hygrometers into the humidor right next to the one that I know is correctly calibrated, they both read 5 to 7 points lower than # 1. If I put any of them back into the salt test dish and wait, they all come right up to 75%.

Any ideas as to what may be going on here?
TomF is offline   Reply With Quote
 


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT -6. The time now is 11:04 PM.


Powered by vBulletin® Version 3.7.4
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
All content is copyrighted jointly by Cigar Asylum and the content provider.