				 Re: How accurate are the Set & Forget systems? 
 
			
			Had my unit since 00 and only had one issue.  There was a run of these that included my batch # where the transistors would fail over time causing the unit to read low thus overhumidifying the cabinets.  I caught this when I noticed the sticks in my singles drawer not burning.  I called Bob up and we figured my unit was in this bad build batch.  He paid for shipping back to him and sent me a loaner unit while mine was being fixed.  Never had a problem since.  Keeps my walk-in at +/- 2% of what i set the humidity to, which in my case is 63% so it will buffer up to 65%.
 Bottom line is that you get what you pay for.  Bob's unit is in a whole different league than beads, moist and air,hydra, etc.....
 
 
 EDIT**********
 
 Btw I believe these units (Bob's) are professionally calibrated in a lab thus if you have other 'salt tested' hydros in the same humidor I would expect that there will be different readings.  Which one I would trust would be simple......The one that was professionally calibrated in a lab and not at home by a salt test.  Your view may of course be different than mine ;o)
 
				__________________Sitting in the Cozumel LCDH ;o)
 
				 Last edited by Mikes; 02-17-2010 at 09:10 AM.
					
					
						Reason: salt test
 |